Holedeck

Español | English

Services

weather

Illumination

Compatible luminaires:

Thanks to its standard dimensions, Holedeck is compatible with all types of lighting fixtures and mounting systems, such as: trays attached to facilities, recessed ceiling, suspended forge, etc. The only consideration to keep in mind is for the lights to no have more than 65 cm diameter, being compatible with any standard false ceiling element of 60 cm. For longer lengths, they should be suspended from the forge.

aaa

Lighting installations network:

Distribution and modulation of the lights is flexible and adaptable to the needs of the particular space thanks to the 80 cm dimension of the modulation system. Different distances between luminaires can be considered . Taking advantange of the hollow space in the forge, the lighting network can be combined with the other facilities.

 

Efficient lighting control:

Systems that regulate lighting and home automation installations are in line with Holedeck's philosophy: doing more with less. Such systems adapt better to the environment, allowing for greater comfort levels . Also, represent significant costs savings, including resources and energy, such as: elimination of installation elements (switches), reduction in the amount of cable needed and allowing for energy savings during the operational stage of the building.

yyyy

Ventilation and Air Conditioning

Air can be distributed through conventional semiflexible ducts or through plenum systems, for which the use of suspended ceiling and tight closures on the side windows will be necessary.

 

aaa

Electricity and telecommunications

aaa

Wiring installations can flow in pipes embedded in the floor, or inside a registrable tile system .

They can also circulate through the suspended ceiling, in cable trays, supported on the nerves of the forge. Fastening elements are elminated, which ease the installation process, resulting in an electrical installation that is fully accessible for registration, permitting maintenance and rencofiguration without the needed of stopping the activity of the building.


yyyy

yyyy

Maintenance, cleaning and registrability

aaa

Holedeck is a 100% registrable system, and by performing plenum ventilation it allows for an easy cleaning of the ducts without requiring demolition or specific equipment. It performs excellent resistance to the Sick Building Syndrome by bactericidal paint coating.

Also, in addition to immediate access to installations, it enables repairs and reconfigurations withot requiring the interruption of the normal activity of the building.


Configuraciones de forjado e instalaciones

a

TYPE 01 Bidirectional system / electricity and networks through strip on the slab

1.Floor

2.Mortar

3.Installations box

4.Radiant floor ducts

5.Insulation / ducts seat

6.Installations tray

7.Holedeck Slab

8.Reinforcement

9.AC Ducts

TIPO01-clean

a


TYPE 01 B bidirectional System / electricity and networks through descending strip

1.Holedeck Slab

2.Climate Control Ducts

3.Reinforcement

4.Installations tray

5.Installations drop tower

TIPO01B

a

TYPE 02 Bidirectional system / electricity and networks through strip / HVAC in plenum

1.Floor

2.Mortar

3.Installations box

4.Radiant floor ducts

5.Insulation

6.Installations tray

7.Holedeck Slab

8.Reinforcement

9.Directing and obturation AC.

TIPO02-clean

a

TYPE 03 Open bidirectional system / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Distribution of installations

6.Installations tray

7.Holedeck Slab

8.Reinforcement

9.CL / AC Ducts

 

TIPO03-clean

a

TYPE 04 Open bidirectional system / Fire cut / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Pieces for fire compartimentation

6.Installations tray

7.Holedeck Slab

8.Reinforcement

9.CL / AC Ducts

TIPO04-clean

aa

TYPE 05 Bidirectional system FIRE SECTORIZATION / Fire barrier by suspended ceiling / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Pieces for fire compartimentation

6.Installations tray

7.Holedeck Slab

8.Fireproof suspended ceiling

9.Reinforcement

10.CL / AC Ducts

TIPO05-clean-saved

aa

TYPE 06 Open bidirectional system / Tramex floor

1.Tramex fixing

2.TRAMEX

3.Lattice slab

4.Holedeck Slab

5.Pieces of reinforcement

TIPO05-clean

aa

TYPE 07 Unidirectional system

1. AC / CL Ducts

2.Holedeck Slab

3.Electricity Tray

4.IT Tray

5.Climate control impeller

6.Lighting

TIPO07-clean

aa

TYPE 08 TRIANGULAR system

1.Climate Control Ducts

2.Holedeck Slab

3.Installations tray

4.Reinforcement

5.Installations drop tower

6.Air impeller

TIPO08-HOLEDECKTRIANGULARBWEB

aa


Hollow dimensions of Ho45

The dimensions of the hollows of the Ho 45 according to the structural requirements, for large spans, correspond to the passage of facilities with medium-high need. Bellow, is described of the compatibility and required space for the air conditioning and electricity systems, and the curve angle required by the semiflexible ducts, is shown.

Example of the available space for services with Ho45 system.


yyyy

Dimensions hollow Ho30

The dimensions of the hollows of the Ho 30 according to the structural requirements, for midsize spans, correspond to the passage of facilities with domestic needs . Bellow, is described the compatibility and required space for the air conditioning and electricity systems, and the curve angle required by the semiflexible ducts, is shown.

Example of the available space for services with Ho30 system.

 


yyyy

 

  • DOWNLOAD: SERVICES DESIGN MANUAL

  • Name:

    Last Name:

    E-mail: *

    Country: *

    Phone:

    Occupation:

    Message:

    CHOOSE DOCUMENTS TO DOWNLOAD: *

    Manual diseño instalaciones Holedeck ESPAÑOL
    Holedeck Services Booklet ENGLISH

    * Required

    I have read and accept the Terms of Use and Privacy *

    Once your information has been submitted, you will start the selected downloads by clicking the links BELOW