weather

illumination

compatible luminaires:

Thanks to its standard dimensions Holedeck is compatible with all types of lighting fixtures and mounting systems: trays attached to facilities, recessed ceiling, suspended wrought, etc. The only consideration to keep in mind is that the lights do not have more than 65 cm diameter, siendo válidas cualquier elemento estándar para falsos techos de 60 cm. For longer lengths should be suspended from wrought.

aaa

Lighting installations Network:

Distribution and modulation of the lights is flexible and adaptable to the needs of space thanks to the modulation 80 cm System. You can see different options distances between luminaires. Gracias a las dimensiones de los huecos del forjado la red de instalaciones de iluminación puede combinarse con el resto de intalaciones.

 

efficient lighting control:

Regulatory systems lighting and home automation installations follow the philosophy that defends Holedeck: do more with less. Get better adaptation of the environment, allowing greater comfort . In addition, , represent a significant savings being listed, resources and energy: installation elements are removed as switches, se reducen los metros lineales de cable y además suponen un ahorro energético importante durante la vida útil del edificio.

yyyy

Ventilation and Air Conditioning

Air can be distributed through conventional semiflexible ducts or through plenum system, for which the use of suspended ceiling and tight closures on the side windows will be necessary.

 

aaa

Electricity and telecommunications

aaa

Wiring installations can flow in pipes embedded in the floor, or inside a registrable tile system .

They can also circulate through the suspended ceiling, en bandejas pasacables, supported on the nerves themselves wrought. Eliminates auxiliary fixtures, easy installation, In addition to making electrical installations fully accessible for registration, maintenance and rencofiguración without stopping the activity space.


yyyy

yyyy

Maintenance, cleaning and registrability

aaa

HOLEDECK is a 100% registrable, and performing plenum ventilation, easy cleaning of the ducts without requiring demolition or specific equipment is possible. It performs excellent resistance to Sick Building Syndrome by bactericidal paint coating.
In addition, , immediate access to installations, enables repairs and reconfigurations withot requiring the interruption of the normal activity of the building.


Configuraciones de forjado e instalaciones

a

TYPE 01 Bidirectional system / electricity and networks through strip on the slab

1.Floor

2.Mortar

3.Installations box

4.Radiant floor ducts

5.Insulation / ducts seat

6.Installations tray

7.HOLEDECK Slab

8.Reinforcement

9.AC Ducts

TIPO01-clean

a


TYPE 01 B bidirectional System / electricity and networks through descending strip

1.HOLEDECK Slab

2.Climate Control Ducts

3.Reinforcement

4.Installations tray

5.Installations drop tower

TIPO01B

a

TYPE 02 Bidirectional system / electricity and networks through strip / HVAC in plenum

1.Floor

2.Mortar

3.Installations box

4.Radiant floor ducts

5.Insulation

6.Installations tray

7.HOLEDECK Slab

8.Reinforcement

9.Directing and obturation AC.

TIPO02-clean

a

TYPE 03 Open bidirectional system / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Distribution of installations

6.Installations tray

7.HOLEDECK Slab

8.Reinforcement

9.CL / AC Ducts

 

TIPO03-clean

a

TYPE 04 Open bidirectional system / Fire cut / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Pieces for fire compartimentation

6.Installations tray

7.HOLEDECK Slab

8.Reinforcement

9.CL / AC Ducts

TIPO04-clean

aa

TYPE 05 Bidirectional system FIRE SECTORIZATION / Fire barrier by suspended ceiling / floor on plots

1.Registrable pavement

2.Access to installations

3.Air diffuser

4.Adjustable plot

5.Pieces for fire compartimentation

6.Installations tray

7.HOLEDECK Slab

8.Fireproof suspended ceiling

9.Reinforcement

10.CL / AC Ducts

TIPO05-clean-saved

aa

TYPE 06 Open bidirectional system / Tramex floor

1.Tramex fixing

2.TRAMEX

3.Lattice slab

4.HOLEDECK Slab

5.Pieces of reinforcement

TIPO05-clean

aa

TYPE 07 Unidirectional system

1. AC / CL Ducts

2.HOLEDECK Slab

3.Electricity Tray

4.IT Tray

5.Climate control impeller

6.Lighting

TIPO07-clean

aa

TYPE 08 TRIANGULAR system

1.Climate Control Ducts

2.HOLEDECK Slab

3.Installations tray

4.Reinforcement

5.Installations drop tower

6.Air impeller

TIPO08-HOLEDECKTRIANGULARBWEB

aa


Dimensions hollow Ho45

The dimensions of the hollows of the floor Ho 45 according to the structural requirements, for large lights, responds to the passage of facilities needs medium-high. Then, se muestra la compatibilidad y espacio requerido para sistemas de aire y electricidad y los radios de curvaturas requeridos en los conductos semiflexibles.

Example of installation ducts in Ho45 system..


yyyy

Dimensions hollow Ho30

The dimensions of the hollows of the floor Ho 30 according to the structural requirements, Midsize lights, responds to the passage of installations with domestic needs . Then, se muestra la compatibilidad y espacio requerido para sistemas de renovación de aire y electricidad y los radios de curvaturas requeridos en los conductos semiflexibles.

Scheme example of passage facilities Ho30.

 


yyyy

 

  • DOWNLOAD: SERVICES DESIGN MANUAL

  • Name:

    Last Name:

    E-mail: *

    Country: *

    Phone:

    You are:

    Message:

    CHOOSE DOCUMENTS TO DOWNLOAD: *

    Manual design facilities SPANISH Holedeck
    Holedeck Services Booklet ENGLISH

    * Required

    I have read and accept the Terms of Use and Privacy *

    Once your data has been submitted, you will start your selected downloads by clicking the links BELOW

 

PRODUCT SAVING AND SUSTAINABILITY ABOUT US REFERENCES CONTACT REFERENCES DOWNLOADS